For laboratory research use only. Every lot independently tested; certificates published by lot.

IGF-1 LR3 lot KB-17790 certificate of analysis

1 mg vial. Tested by ILS Laboratories: purity 99.69% by HPLC-UV, identity confirmed by HPLC-RTM, net content 1.04 mg. Reported September 11, 2026.

Sample summary

ProductIGF-1 LR3 1 mg
LotKB-17790
Purity (HPLC-UV)99.69%
Identity (HPLC-RTM)Confirmed
Net content1.04 mg (+4.0% vs. label)
AppearanceGood (visual)
EndotoxinNot tested for this lot
Microbial analysis (PCR)Not tested for this lot

Laboratory record

Testing laboratoryILS Laboratories
Client on certificateKlow.bio
Certificate numberCOA-2026-BGOBTB
Lab verification access codeF48K7SNT
Received by labSeptember 9, 2026
ReportedSeptember 11, 2026
Release specificationPurity ≥95%; identity confirmed
Against stated specificationMeets

The client listed on the certificate, Klow Labs LLC (klow.bio), is the company that operates IGF-1 LR3 Labs.

Analytical results and methods

TestMethodResult
IdentityHPLC retention-time comparison with a reference standard (HPLC-RTM)Confirmed
PurityHPLC with UV detection (area percent)99.69%
Net contentQuantitation by the laboratory1.04 mg
Bacterial endotoxinLimulus amebocyte lysate (USP <85>)Not tested
Microbial DNAPolymerase chain reaction (PCR) for common microbial contaminantsNot tested
FentanylImmunoassay, 50 ng/mL cutoffNot detected

Verify this certificate

Certificate number COA-2026-BGOBTB, Lab verification access code F48K7SNT.

  1. Find the lot number on your vial. It is printed on the label, for example KB-17790.
  2. Look it up. Enter it at igf1lr3.bio/verify, or open the matching lot in the COA archive.
  3. Check the lab's own record. Go to portal.ils-lab.com (or scan the QR code on the certificate) and enter the lot's verification access code, listed on its lot page, to view the laboratory's own copy of the certificate.
  4. Compare the details. Lot number, the laboratory’s reference numbers, purity and dates should match exactly.

What a certificate of analysis does and doesn't show

  • A COA reports the identity, purity and content of the specific sample tested, on its test date. Results apply to that lot only.
  • HPLC purity measures the main peak relative to other detected components. It does not identify the peak on its own; the separate identity test (HPLC retention-time match) does that.
  • A retention-time match shows the main peak behaves like the reference standard under one method. It is not a mass or structure measurement.
  • Endotoxin and microbial results apply only where those tests appear on the certificate. Lots without them are marked "Not tested".
  • A certificate does not establish stability after the test date or suitability for any particular purpose.

Other IGF-1 LR3 lots

LotVial sizeNet contentPurity (HPLC-UV) Identity (HPLC-RTM)Endotoxin (LAL)Microbial (PCR)ReportedCOA
KB-17790 1 mg 1.04 mg 99.69% Confirmed Not tested Not tested View lot KB-17790

Testing laboratory: ILS Laboratories. Release specification: purity ≥95% by HPLC-UV with identity confirmed by HPLC retention-time match against a reference standard. Results apply only to the lot listed. Certificates list the testing client as Klow.bio / Klow Labs LLC, the company that operates IGF-1 LR3 Labs.

Buy IGF-1 LR3

1 mg vials. Current lot KB-17790 tested at 99.69% purity with identity confirmed by HPLC retention-time match against a reference standard. Current purchasing is available through Klow.bio.